Torus Power Services

Field services for inverters, transformers and battery systems.

Commissioning, maintenance, repair and testing on utility-scale solar and storage plants, closed out with a signed test report.

Illustration of a three-phase inverter output trace with commissioning checks: insulation, voltage verification, grid sync and power export
Inverter commissioning

Cold and hot commissioning for central and string inverters.

From first checks through utility backfeed, performance testing and utility witness testing, we follow the manufacturer’s procedure and document every result, so the plant goes into service with a complete commissioning report.

Cold, before energization

Insulation resistance, wire tightness and torque checks on busbar and cable terminations, equipment and arc-flash label verification, fuse size verification and enclosure inspection.

Hot, energized

DC polarity checks, auxiliary power-up, firmware and parameter setup, Modbus register mapping, utility backfeed, grid synchronization, reactive-power settings, plant performance testing and utility witness tests.

Platforms

OEM platforms we service.

Commissioning, maintenance and repair experience on equipment from these manufacturers. Ask about other platforms; we’ll tell you plainly whether we’ve worked on them.

  • Sungrow
  • Power Electronics
  • ABB
  • FIMER
  • e-Storage
  • BYD
  • TMEIC
  • SMA
Maintenance and repair

Keep inverters and PCS producing.

Preventive maintenance

Scheduled inspections, cleaning, torque and thermal checks, filter and fan service, and firmware updates, to the manufacturer’s maintenance schedule.

Corrective repair

Fault-finding and component replacement on inverters and PCS: power modules, contactors, fuses, fans, control boards and cooling parts.

OEM warranty work

Warranty diagnostics, part replacements and retrofits performed for equipment manufacturers, with the documentation they require.

Illustration of transformer windings beside sweep frequency response traces compared to a baseline
Transformer testing

Pad-mount and step-up transformer testing.

Baseline tests at commissioning and condition checks during operation, so problems show up before a failure takes a block offline.

  • Insulation resistance, polarization index and dielectric absorption ratio
  • Turns ratio and winding resistance on every tap
  • Sweep frequency response analysis (SFRA): a baseline fingerprint, and comparisons after transport or a through-fault
  • Oil sampling for dissolved gas analysis: drawn on site per ASTM D923, analyzed by an accredited lab per ASTM D3612, interpreted per IEEE C57.104
Diagnostics

Find problems before they become failures.

Infrared thermography

Radiometric surveys of switchgear, combiners, inverters and terminations to find hot spots before they fail.

Power quality

Class A logging of harmonics, sags, swells and unbalance, checked against IEEE 519 and the interconnection requirements.

Cable testing and fault location

VLF withstand and tan delta testing on medium-voltage cable, and fault location on DC and medium-voltage runs.

Root-cause investigations

When equipment fails, we find out why.

Field failures go through an 8D investigation. You get a written report with the evidence, not just a replaced part.

  1. Contain

    Contain the problem.

  2. Collect

    Collect the data.

  3. Find

    Find the root cause.

  4. Verify

    Verify the root cause.

  5. Correct

    Correct it and confirm the fix.

Test procedures

What we test, and what you receive.

TestTypical equipmentReferenceYou receive
Inverter cold and hot commissioning1500 V-rated meter, insulation tester, Modbus laptopManufacturer procedure; IEEE 1547 commissioning requirementsCommissioning report with string voltage and polarity log and as-left settings
Insulation, turns ratio and winding resistanceInsulation tester, TTR test set, micro-ohmmeterIEEE C57.12.90; ANSI/NETA ATSIR, PI and DAR values; ratio error; winding resistance by tap
Sweep frequency response (SFRA)SFRA analyzerIEEE C57.149; IEC 60076-18Frequency response traces and comparison to baseline
Transformer oil (DGA)Sampling kit; accredited third-party labASTM D923; ASTM D3612; IEEE C57.104Lab report: dissolved gases, moisture and oil quality
Infrared thermographyRadiometric infrared cameraANSI/NETA MTSThermal images with temperature-rise ratings
Medium-voltage cable testingVLF test setIEEE 400.2Withstand and tan delta results
Illustration of a QA/QC inspection checklist with hold points from conduit before backfill to punch list closed
Owner’s QA/QC

Independent quality checks for owners and developers.

We check that construction matches the drawings, the manufacturer’s instructions and the NEC.

  • Hold-point inspections at each stage of construction
  • Punch lists with photos and code references
  • Re-inspection until every item is closed
Next step

Need commissioning or a service call?

Tell us the site, the equipment and what’s happening. For an outage, call and we’ll talk through next steps.